Insights · Environment

What Your Indoor Air Data Is Really Telling You

Your monitor shows three numbers. Each answers a different question than you think.

Focus: Reading CO₂, particle and VOC dataAudience: Homeowners · Building Operators · Facility ManagersPublished: November 8, 2026Published by: Airiva Inc.

Introduction

The 1,000 ppm Problem

Back in 1989, the main ventilation standard used across North America included a limit for carbon dioxide indoors: 1,000 parts per million. Later editions dropped it, mostly because people kept reading it as the point where air turns unhealthy. It was never meant to say that.

The idea stuck around anyway. ASHRAE, the engineering society behind that standard, said in its 2025 position paper on indoor CO₂ that people still quote an ASHRAE limit of 1,000 ppm that no longer exists.

That same number now shows up on air monitors in homes, offices and classrooms, usually next to two other readings: fine particles, and something called total VOCs, which lumps chemical vapours together. They sit in a tidy row on the screen, so it feels natural to read them all the same way.

We think that’s where most people go wrong. Each reading answers its own fairly narrow question, and none of them tells you whether the air in the room is healthy, even though that’s why almost everyone buys a monitor in the first place.

A typical monitor screen, decoded Values are illustrative, not measured
Carbon dioxide
1,140ppm
Ventilation gauge
Good for
Telling you whether enough fresh air is coming in for the people in the room.
Blind to
Smoke, fumes from furniture or paint, mould, and anything people don’t breathe out.
Fine particles (PM2.5)
18µg/m³
Smoke alarm
Good for
Showing when something put particles in the air and when they cleared.
Blind to
The exact amount. Depending on the source, it can read high or low.
Total VOCs
650ppb
Change detector
Good for
Noticing that the chemical mix in the room has shifted.
Blind to
Which chemicals are there, or whether any of them are harmful.
Section 01

CO₂ Is About Breathing

Most of the carbon dioxide indoors comes from people breathing out. You can think of the reading as a measure of second-hand breath, or how much of the room’s air has already been through someone else’s lungs. Add people or cut the fresh air, and it goes up.

That makes it useful for judging ventilation and not much else. ASHRAE’s 2025 position says outright that CO₂ doesn’t tell you overall air quality. The CO₂ reading won’t budge for fumes from a new couch, wildfire smoke leaking in, or dust caught in a filter. Even 1,000 ppm, according to ASHRAE, only roughly lines up with about 8 litres of fresh air per second for each person.

It also depends on the room. ASHRAE points out that a packed conference room can run well over 2,500 ppm and still be ventilated exactly the way the standard intends. A monitor that flashes red at 1,000 has no way of knowing that.

What Health Canada says

For homes, Health Canada’s guideline is 1,000 ppm averaged over 24 hours. People tend to skip over the averaging part, and it’s the part that matters most. If your living room hits 1,100 for an hour after friends come for dinner, you haven’t broken the guideline. A bedroom that sits around 1,400 every night with the door shut is a different story.

So when the monitor turns red, the more useful question is how long it stays red.

When the sensor calibrates itself on the wrong air

There’s another wrinkle, and it’s inside the device. A lot of CO₂ sensors correct their own drift by remembering the lowest reading from the past week or so and treating it as fresh outdoor air. Senseair, one of the big sensor manufacturers, explains this on its website. It also says plainly that the method won’t work in a space that’s occupied around the clock and never gets down to outdoor levels.

It’s a bit like a bathroom scale that resets to zero whenever it thinks nobody is on it. If someone is always standing on it, it zeroes with them still there, and every weight after that reads light. A closed-up house in a Canadian January, with someone home all day, is pretty close to that situation.

Checking takes about ten minutes. Put the monitor outside, or next to a wide-open window. Outdoor CO₂ averaged roughly 426 ppm worldwide in 2024, a bit higher near busy roads. If your monitor is way off that number outdoors, we wouldn’t lean on it indoors.

To be fair to the technology, CO₂ is the most reliable of the three readings. In a 2024 study, researchers at the University of British Columbia set 87 identical monitors next to professional instruments, and the CO₂ readings met the manufacturer’s accuracy claims. A 2023 test of seven home monitors came to the same conclusion, with every device acceptable on CO₂.

Section 02

Particle Readings Work Like a Smoke Alarm

Cheap particle sensors don’t actually weigh anything. They shine a small light through a stream of air, count the flashes as particles drift past, and then estimate the weight using assumptions about what those particles are probably like. Cooking smoke, dust and humid air don’t all fit those assumptions, so the estimate wanders.

How far does it wander? In the UBC study, particle readings were off by about 27 percent, close to twice the error the manufacturer listed. In the 2023 home monitor test, only one product hit the accuracy target when compared with a research-grade meter. Other recent work points to humidity as the biggest source of error, and finds the same kind of sensor reading too low in dusty air.

A smoke alarm tells you something is burning and when it stopped. Nobody expects it to weigh the smoke.

For us, that’s the most useful way to think about a PM2.5 reading. The amount is shaky, but the timing is usually good. In the UBC study, the monitors went up and down in step with the professional instrument even when their numbers didn’t agree.

Health Canada’s approach suits this. It doesn’t set an indoor limit for fine particles at all, saying the evidence doesn’t allow one to be set. So instead of worrying about whether 18 is a good number, we’d ask two other questions. Is the air inside usually cleaner than outside? And after you cook, how long does the reading take to come back down? If it drops quickly, your range hood and ventilation are doing their job. If it hangs around for an hour, that’s worth looking into.

Section 03

TVOC Is the Number to Trust Least

VOCs covers hundreds of different chemicals, from harmless cooking smells to formaldehyde. Health Canada has limits for individual ones, such as formaldehyde, toluene and xylenes. It has no limit for the total.

The sensors struggle as well. In the UBC study, TVOC readings were off by as much as 79 percent, well beyond what the manufacturer claimed, and this was a well-known model with a third-party accuracy accreditation. Part of the gap came from the monitors and the reference instrument being tuned to different chemicals, so they weren’t really measuring the same thing. Even so, their readings rose and fell together.

We treat TVOC like noise heard through a wall. You know it got louder next door, but you can’t tell whether it’s music or an argument. That can still be handy after painting, a new sofa or a big cleaning day, because you can see when the spike started and whether it’s settling. If you’re genuinely worried about a particular chemical, though, a lab air test will tell you far more than any monitor can.

Section 04

Each Number at a Glance

Reading Trust it for Don’t trust it for Canadian reference
CO₂ Whether fresh air keeps up with the people in the room Smoke, chemicals, particles, or whether the air is healthy 1,000 ppm, averaged over 24 hours
Fine particles When something starts, peaks and clears The exact amount in the air No limit set; lower is better
Total VOCs Noticing that something changed Which chemicals, or how risky they are No limit for the total; limits exist for single chemicals
24 hrs The averaging time behind Health Canada’s 1,000 ppm CO₂ guideline
1 of 7 Home monitors that met the particle accuracy target in a 2023 test
79% Largest TVOC error found across 87 monitors in a 2024 UBC study
What This Changes

Watch How the Numbers Move

If there’s one habit worth building, it’s paying more attention to how the readings move than to the readings themselves. Most of the problems we’ve described come down to the exact amount. Most of what these monitors do well comes down to timing.

The team behind the 2023 home monitor test ended up somewhere similar. In their view accuracy matters, but so does how a device shows its data, since the whole point is helping people make decisions about the air they’re breathing.

At Airiva we work by a simple rule we call performance before plaque: measure how a building actually behaves before giving it a badge. The same thinking applies to monitors. A sensor on the wall doesn’t prove much on its own, and the UBC results show that a certification on the box doesn’t guarantee accuracy in the room. The data starts to mean something once someone has checked that it reads true and understands what it can and can’t answer.

Conclusion

Where to Look Next

When CO₂ climbs, look at the ventilation. When particles spike, find the source and watch how quickly they clear. When TVOC jumps, something in the room has changed, and it’s worth working out what.

None of these readings can tell you by itself that your air is safe, or that it’s harmful. That still takes someone who understands what each one measures. What a monitor does well is point you to the next thing worth checking. Used that way, it earns its spot on the shelf.

About Airiva Airiva is an Alberta-based indoor air quality advisory firm. We help building owners and developers decide what to measure, where to measure it, and which devices are worth trusting, so the numbers on the wall answer the questions they’re meant to. Sensing what matters.
Indoor Air Quality CO₂ Monitoring Fine Particles VOCs Health Canada ASHRAE Airiva

Published by Airiva Inc., an Alberta-based indoor air quality advisory firm. No monitor brands are named and no product endorsement is intended; both studies cited identify the products they tested, and those names were deliberately left out.

Sources read, all published or updated within the last five years: ASHRAE Position Document on Indoor Carbon Dioxide, approved February 12, 2025 (source for the 1989 history, the 8 L/s figure, the conference-room example and the 2024 outdoor CO₂ average); Health Canada, Indoor air quality resources for professionals, page updated September 2025 (CO₂ guideline value and averaging time, single-chemical VOC limits, and PM2.5 listed among contaminants without an exposure limit); Senseair, “The Senseair ABC-algorithm” (manufacturer web page, current); Manu and Rysanek, “A Co-Location Study of 87 Low-Cost Environmental Monitors,” Buildings 14(9), 2024, University of British Columbia; Peters and Zhen, “Evaluating Indoor Air Quality Monitoring Devices for Healthy Homes,” Buildings 14(1), 2023; Mathieu-Campbell et al., Atmospheric Measurement Techniques, 2024; Kaur et al., Atmospheric Measurement Techniques 19, 2026.

← Back to Insights